NuDAM-6521
• 61
@Description
Read module‘s name.
@Syntax
$(Addr)M<CR>
$
Command leading code.
(Addr) Address
ID
M
Read module name
@Response
!(Addr)(ModuleName) <CR>
or
?(Addr)<CR>
!
Command is valid.
?
Command is invalid.
(Addr) Address
ID.
(ModuleName)
NuDAM module‘s name.
@Example
User command:
$30M<CR>
Response:
!306521<CR>
!
Command is valid.
30 Address
6521
ND-6521 (RS-422/485 to RS-232 converter)