72

NuDAM-6521

5.4.16 Data Pass

@Description
Pass the data to RS-232 device.

@Syntax
(Delimiter)(Addr)(Data)<CR>

(Delimiter)

Data pass delimiter character

(Addr)

Address ID (2-character)

Data

Data to the RS-232 device, up to 80 bytes of data can
be passed by one command

@Response
No response

@Example

User command:

{30ABCDEFGHIJ<CR>

Response:

{

Use { as Data Pass delimiter

30 Address

ID

ABCDEF

Data pass to RS-232 device (if X.0 = 0, don’t append
<CR>)

ABCDEF<CR> Data pass to RS-232 device (if X.0 = 1, append <CR>

mode)