5 communications with ipmc, 6 ipmi sensors list, Communications with ipmc – ADLINK cPCI-6210 User Manual
Page 134: Ipmi sensors list
![background image](/manuals/733536/134/background.png)
120
IPMI User Guide
9.5
Communications with IPMC
Operating systems need to use a serial port to communicate with
the IPMC. The resource setting of the serial port must be IO:
0x2F0 and IRQ: 7. The communication setting of the serial port
must be BaudRate: 9600, DataBit: 8, ParityCheck: None, StopBit:
1, and FlowControl: None. In Windows XP, use "COM6" to com-
municate with the IPMC.
9.6
IPMI Sensors List
Sensor
Number
Sensor name
Normal
Reading
Sensor Reading Value of
IPMI Get Sensor Reading
Command
01h
BMC Watchdog
Timeout action:
000b = no action
001b = Hard Reset
000b = Power Down
011b = Power Cycle
100b - 111b = reserved
02h
3.3V
3.3 V
Raw data of 3.3V sensor
03h
5V
5 V
Raw data of 5.0V sensor
04h
12V
12 V
Raw data of 12.0V sensor
05h
CPU Temp
40ºC
Raw data of CPU Temp sensor
06h
SYSTEM Temp
25ºC
Raw data of SYSTEM Temp
sensor