Com1/debug switch (sw8), Com1 mode selection switches (sw9,sw10) – ADLINK cPCI-6210 User Manual

Page 62

Advertising
background image

48

Board Interfaces

COM1/Debug Switch (SW8)

Switch SW8 sets the COM1 serial port as a standard RS-232
serial port or as an IPMI debugging port.

Table 4-25: COM1/Debug Switch Settings

COM1 Mode Selection Switches (SW9,SW10)

Switch SW9 sets the COM1 serial port to RS-232 or
RS-422/485 mode and SW10 sets COM1 to RS-422 or RS-485
mode. When the SW9 is set to RS-232 mode, SW10 has no
function.

Table 4-26: COM1 Mode Selection Switch SW9 Settings

Table 4-27: COM1 Mode Selection Switch SW10 Settings

Mode

1

2

3

4

RS-232 COM port (default)

ON

ON

OFF

OFF

IPMI debugging port

OFF

OFF

ON

ON

Mode

1

2

RS-232 (default)

Not Used

ON

RS-422/485

Not Used

OFF

Mode

1

2

RS-485

Not Used

ON

RS-422

Not Used

OFF

ON

1 2 3 4

ON

1

2

3

ON

1 2

Advertising