COM1/Debug Switch (SW8)
Switch SW8 sets the COM1 serial port as a standard RS-232
serial port or as an IPMI debugging port.
Table 4-25: COM1/Debug Switch Settings
COM1 Mode Selection Switches (SW9,SW10)
Switch SW9 sets the COM1 serial port to RS-232 or
RS-422/485 mode and SW10 sets COM1 to RS-422 or RS-485
mode. When the SW9 is set to RS-232 mode, SW10 has no
function.
Table 4-26: COM1 Mode Selection Switch SW9 Settings
Table 4-27: COM1 Mode Selection Switch SW10 Settings
Mode
1
2
3
4
RS-232 COM port (default)
ON
ON
OFF
OFF
IPMI debugging port
OFF
OFF
ON
ON
Mode
1
2
RS-232 (default)
Not Used
ON
RS-422/485
Not Used
OFF
Mode
1
2
RS-485
Not Used
ON
RS-422
Not Used
OFF
ON