cExpress-HL

Feature

Options

Description

Active Cooling Trip Point

Disabled
40 C
50 C
60 C
70 C
BMC Default

Active Cooling Trip Point.

Passive Trip Point

Disabled
90 C
80 C

This value controls the temperature of the ACPI Passive Trip
Point - the point at which the OS will begin throtting the
processor.

Passive TC1 Value

1

This value sets the TC1 value for the ACPI Passive Cooling
Formula. Range 1 - 16

Passive TC2 Value

5

This value value sets the TC2 value for the ACPI Passive
Cooling Formula. Range 1 - 16

Passive TSP Value

10

This item sets the TSP value for the ACPI Passive Cooling
Formula. It represents in tenths of a second how often the OS
will read the temperature when passive cooling is enabled.
Range 2 - 32

Watchdog ACPI Even Shutdown

Disable
Enable

Enable / Disable Watchdog ACPI Even Shutdown.

7.3.13 Miscellaneous

Feature

Options

Description

Miscellaneous Info

only

High Precision Timer

Enabled
Disabled

Enable or disable the High Precision Event Timer.

Security Info

only

BIOS Security Configuration

Submenu

Trusted Computing

Submenu

Intel TXT(LT) Configuration

Disable
Enable

Enables or Disables Intel(R) TXT (LT) support.

7.3.13.1 Miscellaneous > BIOS Security Configuration

Feature

Options

Description

BIOS Security Configuration

Info only

Global SMI Lock

Enabled
Disabled

Enable or disable SMI lock.

BIOS Lock

Disable
Enable

Enable or disable BIOS lock enble (BLE) bit.

GPIO Lock

Disable
Enable

Enable or disable GPIO lockdown.

BIOS interface Lock

Disable
Enable

Enable or disable BIOS interface lockdown.

RTC RAM Lock

Disable
Enable

Enable or disable bytes 38h-3Fh in the upper and lower 128-
byte bank of RTC RAM lockdown.