12

SECTION C - STRUCTURAL SUPPORT AND GUIDING

ANCHOR PLATE ASSEMBLY (AP)

1.. .The.anchor.plate.support.assembly.is.designed.to.provide.maximal.

support.to.vertical.sections.and.to.provide.fixed.point.support.for.

horizontal.sections.

2.. .The.plate.support.must.be.attached.to.the.building.structure.or.sup-

ported.with.rigid.structural.members.(see.figure 22.and.table 12.for.

bracing.dimensions)

3.. DO NOT ATTACH THE ANCHOR PLATE TO COMBUSTIBLE CON-

STRUCTION...If.unavoidable,.use.the.Ventilated.Anchor.Plate.support.

assembly..

4.. .The.anchor.plate.consists.of.a.plate.and.eight.clamp.flange...See..

figure 21..for.sectional.details.for.plate.support.

5.. IMPORTANT: The surfaces of the male and female couplings

in contact with the plate of the anchor plate assembly must be

coated with inner joint sealant.

6.. .There.are.two.ways.of.assembling.parts.on.the.support...You.may.

choose.your.method.depending.on.your.situation.

6.1..The.first.method.consists.of.assembling.two.parts.and.the.anchor.

plate.on.the.side.and.then.installing.this.assembly.on.the.support.

structure...This.method.is.easier.and.faster.to.install,.but.requires.

enough.clearance.to.insert.the.complete.assembly.through.the.sup-

port.structure.opening...If.there.is.a.tee.or.elbow.upstream.of.the.

anchor.plate,.you.may.not.have.enough.clearance...Also.consider.

the.weight.of.the.assembled.parts.and.make.sure.you.have.a.safe.

manner.of.lifting.the.assembly.

INSTALLATION STEPS FOR FIRST METHOD (refer to figure 23)

1.. .Place.the.part.that.will.be.upsteam.of.the.support.on.the.floor.

2.. .Apply.a.bead.of.inner.joint.sealant.on.the.male.coupling.flange.

3.. .Slide.the.plate.of.the.anchor.plate.support.over.the.coupling.

4.. .Apply.a.second.bead.of.sealant.on.the.plate.around.the.male.

coupling.where.the.flange.of.the.female.coupling.of.the.next.part.

will.mate.

5.. .Place.the.second.part.over.the.plate...Make.sure.the.sealant.com-

pletely.fills.joints.between.the.plate.and.the.female.coupling.

6.. .Use.eight.clamp.flanges.and.bolts.to.tightly.clamp.the.parts.to.

the.support...

7.. .Insert.the.assembly.on.the.support.structure.and.fix.the.plate.to.

the.structure.using.the.supplied.hardware.

6.2..The.second.method.is.applicable.when.the.plate.of.the.anchor.plate.

support.needs.to.be.installed.first,.as.when.there.is.a.tee.or.elbow.

upstream.of.the.support...May.require.at.least.two.persons.to.complete.

the.installation.

INSTALLATION STEPS FOR SECOND METHOD (refer to figure 24)

1.. .Fix.the.plate.of.the.anchor.plate.support.to.the.structure.using.

the.supplied.hardware.

2.. .Apply.a.bead.of.inner.joint.sealant.on.the.male.coupling.flange.

of.the.part.before.the.support.

3.. .Insert.the.male.coupling.of.the.part.in.the.plate.opening.

4.. .You.may.hold.it.using.two.clamp.flanges.placed.at.180°.and.

bolted.to.the.anchor.plate...

5.. .Apply.a.bead.of.sealant.on.the.plate.around.the.male.coupling.

6.. .Place.the.second.part.over.the.plate...Make.sure.the.sealant.com-

pletely.fills.the.joint.between.the.plate.and.the.female.coupling.

7.. .Fix.the.assembly.by.clamping.it.with.four.clamp.flanges.on.the.

unused.flange.positions.

8.. .Remove.the.first.two.clamp.flanges.and.finish.clamping.the.as-

sembly.

VENTILATED ANCHOR PLATE (APV)

1.. .Use.for.same.application.as.the.anchor.plate,.but.can.be.attached.to.

combustible.construction.

2.. .Usually.uses.as.roof.support...See.section.D.for.details.on.how.to.

install.at.the.roof.level.

3.. .Installation.is.done.the.same.manner.as.the.anchor.plate.

4.. .See.Figure 25 .for.opening.dimensions.through.combustible.con-

struction.

5.. .Do.not.block.or.obstruct.openings.in.the.plate...They.are.intended.to.

minimize.heat.accumulation.

Figure 21 - Sectional detail for plate support

LENGTH ANCHOR PLATE (APL)

1.. .Use.for.same.application.as.the.anchor.plate.(AP).

2.. .It. is. composed. of. a. straight. section. -. with. an. effective. length. of............

3.3/4”.integrated.into.a.support.plate.(see.Figure 20.for.the.detail.of.

the.part).

3.. .Unlike.the.anchor.plate.(AP),.the.Length.Anchor.Plate.(APL).doesn’t.

need.any.clamp.flange.(and.its.hardware).for.its.installation,.so.it.is.

easier.and.faster.to.isntall.

4.. .The.APL.must.be.attached.to.the.building.structure.or.supported.by.

rigid.NON-COMBUSTIBLE.structural.members.(see.Figure.22.and.

Table.12.for.bracing.dimensions).

Installation.steps.for.the.APL

1.. .Fix.the.plate.of.the.APL.to.the.structure.using.the.supplied.hardware.

2.. .Follow.the.steps.of.the.«Chimney.and.fitting.assembly».section.in.

the.section A.on.page.5.to.connect.the.couplings.to.the.APL.with.

the.parts.downstream.and.upstream.

Figure 20 - Length Anchor Plate (APL)