DuraVent DuraStack Installation User Manual

Page 24

Advertising
background image

NOTE:.DIAGRAMS.&.ILLUSTRATIONS.ARE.NOT.TO.SCALE.

24

VARIABLE LENGTH

1.. .The.variable.length.(LV).is.used.only.to.make.odd.lengths,.it.doesn’t.

compensate.thermal.expansion..See.figure 65 for typical location.

2.. .The.variable.length.assembly.includes.a.sliding.flanged.female.cou-

pling,.a.flanged.retaining.band,.a.locking.band,.a.insulation.band.and.

split.outer.casing...Inner.flue.sealant.S-2000.or.S-650.is.necessary.

depending.on.the.flue.gas.temperature.

3.. .Installation steps :

a..Measure.the.distance.required.for.the.variable.length...See figure

59.

b..Cut.the.inner.wall.at.the.dimension.found.at.point.‘a.’.plus.1”...

Cut.the.split.outer.casing.at.dimension.plus.5/8”...Then.cut.the.

insulation.band.at.dimension.(DIS.only)...See.figure 60.

c..Install.the.interior.assembly.between.the.two.parts...Put.one.

bead.of.sealant.between.the.couplings.flanges.as.a.regular.length.

installation...See.figure 61.

d..Slide.down.the.female.coupling.over.the.male.coupling.of.down-

stream.part.and.fill.the.gap.between.the.female.coupling.and.the.

inner.wall.with.S-2000.or.S-650.sealant...See.figure 62.

e..Slide.down.the.retaining.band.to.the.female.coupling.to.mate.

their.flanges.and.tighten.the.band...Then,.install.the.locking.band.

over.those.flanges..See.figure 63.

f.. Install.the.insulation.over.the.inner.wall.(DIS.only)...See figure

64.

Figure 59-

Variable length, Installation step A

Figure 60 -

Variable length, Installation step B

Figure 64 -

Variable length, Installation step F

Figure 65 -

Variable length, Installation step G

Figure 61 -

Variable length, Installation step C

Figure 62 -

Variable length, Installation step D

Figure 63 -

Variable length, Installation step E

Slide down the female coupling

and fill the gap with sealant

Slide down the retaining band and

tighten the band and install the locking

band over the flanges

Install the insulation (DIS only)

Distance X

Cut to X + 1”

Cut to X + 5/8”

Cut to X

(DIS only)

Cut 1.25” in the bend to

clear the locking band

Install interior assembly

between two parts

Install the outer shell by inserting

the crimped end under the male

coupling first

Tighten the bolts

and install the

locking bands

Advertising