18

SECTION E - TERMINATIONS, STARTING ADAPTORS, DRAIN

LENGTH AND RELIEF VALVE

STARTING ADAPTORS

Single Wall Adaptor (SWA)

1.. The.Single.Wall.Adaptor.is.used.as.an.appliance.connector...It.is.de-

signed.to.be.clamped.with.a.Retaining.Band.and.a.locking.band.over.

a.shank.type.flue.gas.outlet.

2.. First,.slide.the.retaining.band.over.the.appliance.outlet.and.tighten.it.

with.supplied.bolt..(See.figure 38).

3.. Add.a.bead.of.sealant.about.1/8”.on.the.flange.of.the.retaining.band.

and.one.on.the.flange.of.the.adaptor.(SWA).and.mate.those.two.flanges.

together...Be.sure.to.fill.all.the.gaps.with.S-2000.sealant..(See.figure

39 and figure 40).

4.. Tighten.the.Locking.Band.to.hold.and.seal.the.adaptor.in.place...See.

Figure 41.for.typical.installation.

ANSI Flange Adaptor (FA)

1.. .The.Flange.Adaptor.(FA).is.intended.for.use.as.a.connection.to.a.class.

125.or.150.ANSI.pipe.flange.

2.. This.type.of.connection.requires.a.flange.gasket.and.bolt.set.provided.

by.the.installer...The.gasket.and.bolts.are.typically.sold.by.pipe,.valve.

and.fittings.houses.as.‘NBG’.set.. Figure 42..illustrates.a.typical.instal-

lation.

3.. An.outer.band.with.insulation.is.included.to.close.the.installation.

Flanged Adaptor (FHA)

1.. The.Flanged.Adaptor.(FHA).is.used.to.connect.the.DIS./.DAS.chimney.

to.flanged.appliance.outlets.other.than.those.with.ANSI.pipe.flanges.

2.. The.adaptor.is.designed.to.sandwich.an.1/2.inch.flange.between.two.

half.ring.and.the.appliance.flanged.outlet...The.Flange.Adaptor.comes.

with.beam.clamps.to.clamp.the.FHA.to.the.appliance..See.Figure 43.

DIS/DCT, DCT/DIS, DAS/DCT, DCT/DAS Adaptor

1.. Used.to.connect.model.DIS./.DAS.chimney.to.model.DCT.chimney...

See.Figure 44.

Figure 38 - Single wall adaptor

Figure 39

Figure 40

Figure 41

APPLIANCE

OUTLET

Insert and tighten

the band in place

APPLIANCE

OUTLET

Apply bead

of sealant

APPLIANCE

OUTLET

Insert the

coupling end

APPLIANCE

OUTLET

Tighten the

locking band

OTHER ADAPTORS

Female Single Wall Adaptor (FSWA)

1.. The.Female.Single.Wall.Adaptor.is.used.as.a.connector.to.specialised.

component. or. existing. chimney. connection.. . It. is. designed. to. be.

clamped.with.a.Retaining.Band.and.a.locking.band.over.a.shank.type.

flue.gas.inlet.

2.. First,.slide.the.retaining.band.over.the.system.inlet.and.tighten.it.with.

supplied.bolt..(See.figure 38a).

3.. Add.a.bead.of.sealant.about.1/8”.on.the.flange.of.the.retaining.band.

and.one.on.the.flange.of.the.adaptor.(SWA).and.mate.those.two.flanges.

together...Be.sure.to.fill.all.the.gaps.with.S-2000.sealant..(See.figure

39a and figure 40a).

4.. Tighten.the.Locking.Band.to.hold.and.seal.the.adaptor.in.place...See.

Figure 41a.for.typical.installation.

Female ANSI Flange Adaptor (FFA)

1.. .The.Female.Flange.Adaptor.(FFA).is.intended.for.use.as.a.connection.

to.a.class.125.or.150.ANSI.pipe.flange.

2.. This.type.of.connection.requires.a.flange.gasket.and.bolt.set.provided.

by.the.installer...The.gasket.and.bolts.are.typically.sold.by.pipe,.valve.

and.fittings.houses.as.‘NBG’.set.. Figure 42..illustrates.a.typical.instal-

lation.

3.. An.outer.band.with.insulation.is.included.to.close.the.installation.

Figure 38a - Female Single wall

adaptor

Insert and tighten

the band in place

INLET

Figure 39a

INLET

Apply bead

of sealant

Insert the

coupling end

Figure 40a

Tighten the

locking band

INLET

Female.Flanged Adaptor (FFHA)

1.. The.Flanged.Adaptor.(FFHA).is.used.to.connect.the.DIS.chimney.to.

flanged.appliance.outlets.other.than.those.with.ANSI.pipe.flanges.

2.. The.adaptor.is.designed.to.sandwich.an.1/2.inch.flange.between.two.

half.ring.and.the.appliance.flanged.outlet...The.Flange.Adaptor.comes.

with.beam.clamps.to.clamp.the.FFHA.to.the.appliance..See.Figure 43.

INLET

Figure 41a