NOTE:.DIAGRAMS.&.ILLUSTRATIONS.ARE.NOT.TO.SCALE.

4

WARNINGS

DO NOT INSTALL ANY TYPE OF INSULATION IN THE

REQUIRED CLEARANCE SPACES SURROUNDING

THE CHIMNEY.

OPENING THROUGH COMBUSTIBLE CONSTRUCTION

The.following.table.serves.to.identify.the.minimum.opening.required.when.

installing.a.chimney.through.a.floor,.wall.or.roof.made.of.combustible.

material...See.table 3.and.figure 1.

DIS

PART NUMBERS

These.instructions.identify.major.model.DIS./.DAS.parts.by.name.and.

part.number.

Example:

DIS.36”.length.with.inside.diameter.14”.made.of.ss316.inner.flue.and.

ss304.outer.casing.

.

DIS. 14. L36. BC

.

Model. Dia.. Part. Material

DAS.30°.elbow.with.inside.diameter.22”.made.of.ss304.inner.flue.and.

galvalume.outer.casing.

.

DAS. 22. E30. CE

.

Model. Dia.. Part. Material

DIS.wall.support.for.8”.diameter.chimney.made.of.galvalume.

.

DIS. 8. WS. E

.

Model. Dia.. Part. Material

Use only factory-supplied components. Failure to do so will

void the certification and the warranty of the chimney system.

EFFECTIVE LENGTH

DIS / DAS

When.assembling.two.parts.together,.the.joint.will.overlap.5/8”...So.ef-

fective.length.is.nominal.length.minus.5/8”

Example:

.

.

........Effective length

.

L36.

35-3/8”

.

L24.

23-3/8”

.

L18.

17-3/8”

.

L12.

11-3/8”

Figure 1

B = A + 4”

OPENINGS - Minimum open-

ing required when installing

a chimney through a floor,

wall or roof made of com-

bustible material.

A

B

C

Inside diameter

B.H.A Chimney

1400°F Chimney

Grease Duct

Ø5” to Ø36”

1”

1”

2”

Table 1 - Minimum air space clearance to combustible construc-

tion model DIS

Inside diameter

B.H.A Chimney

1400°F Chimney

Ø5” to Ø36”

4”

4”

Table 2

Inside diameter (A)

Roof / Floor (C)

1400°F Chimney (C)

Ø5” to Ø10”

Inside Ø + 12”

Inside Ш + 12”

Ш12” to Ø36”

Inside Ø + 12”

Not listed

Table 4 - Minimum openings

Chimney outside diameter

2” Insulation

Chimney inside diameter

Clearance opening

Inside diameter (A)

Roof / Floor (C)

Wall (C)

Ø5” to Ø10”

Inside Ø + 8”

Inside Ш + 8”

Ш12” to Ø36”

Inside Ø + 8”

Not Listed

Table 3 - Minimum openings

DAS

Minimum. air. space. clearance. to. combustible. construction. to. DAS.

chimney.is.4”.

DAS

CLEARANCES

DIS

Minimum air space clearance to combustible construction to model

DIS Chimney is 1”.
For non-combustible construction, maintain clearances as required

for installation, access for inspection or per local code.