Location Requirements:

WARNING:

This grill is Design Certified for use outdoors

only and is not intended for use on recreational

vehicles or boats.

The “Infrared Elite” is designed to be attached to the optional

pedestal / cart or be permanently installed on a free-standing

masonry or other suitable patio fixture.

Minimum clearance of a mobile grill to any adjacent

combustible construction can be found in Table A.

Table A.

If you are installing your grill as a brick-in or masonry supported

variation, it should be located so the ventilation louvers remain

clear of all obstructions. The louvers are located in the front face

of the grill and at the rear of the hood. Accumulation of debris in

the louvers can cause the grill to overheat. There should be no

combustible construction above the grill within 6 feet.

The installation of your grill must conform to local codes or, in

the absence of local codes, with either the National Fuel Gas Code,

ANSIZ223, 1 or CAN/CGA-B149.1, Natural Gas Installation Code or

CAN/CGA-B149.2, Propane Installation Code.

Combustible Non-Combustible

Construction

Construction

Sides

12”

0”

Back

12”

0”