Gas requirements – Golden Blount Infrared Elite User Manual

Page 8

Advertising
background image

8

GAS REQUIREMENTS:

WARNING: WHEN PURCHASED FOR USE WITH LP GAS, THE

“INFRARED ELITE” GRILL COMES WITH A REGULATOR ASSEMBLY

THAT USES A QUICK-CONNECT TYPE COUPLING. THIS TYPE COUPLING

CAN ONLY BE USED WITH QUICK-CONNECT STYLE TANK VALVE.

WARNING: THE GAS SUPPLY HOSE SHOULD BE INSPECTED PRIOR

TO EACH USE. DO NOT USE A GAS HOSE THAT HAS ABRASIONS, CUTS

OR EXCESSIVE WEAR.

WARNING: IF THE OUTDOOR COOKING GAS APPLIANCE IS NOT IN

USE, THE GAS MUST BE TURNED OFF AT THE SUPPLY CYLINDER.

STORAGE OF AN OUTDOOR COOKING GAS APPLIANCE INDOORS

IS PERMISSABLE ONLY IF THE CYLINDER IS DISCONNECTED

AND REMOVED FROM THE OUTDOOR COOKING GAS APPLIANCE.

CYLINDERS MUST BE STORED OUTDOORS OUT OF REACH OF

CHILDREN AND MUST NOT BE STORED IN A BUILDING, GARAGE OR

ANY OTHER ENCLOSED AREA.

The “Infrared Elite” is offered in one of two gas configurations LP or

Natural gas. LP models include pressure regulator and hose assembly.

Natural gas models require a separate regulator supplied with grill. LP

models require a standard 20-lb. LP cylinder with QC

(quick connect) style valve.

Please Note: The Pressure regulator and hose assembly with the outdoor

cooking gas appliance must be used. Replacement pressure regulators

and hose assemblies must be those specified for the “Infrared Elite”.

Gas Supply Specifications

SUPPLY

OPERATING

MAIN BURNER

BURNER

GAS TYPE

PRESSURE

PRESSURE

ORIFICE SIZE

INPUT

Natural

14.0” WC MAX

4.0” WC

#49

15,000 BTU/HR

5.0” WC MIN

LP

14.0” WC MAX

11” WC

#57

15,000 BTU/HR

12.0” WC MIN

Advertising