Ac power inlet panel, Ac power cord, Power switch/circuit breaker – Dukane Ultrasonic Generator 403-575-00 User Manual

Page 106: Chassis ground stud, 120 volt line cord a b c

Advertising
background image

AC Power Inlet Panel

The optional AC power inlet panel is described here.

AC Power Cord

The AC power cord (

A

in Figure 8-2) is appropriately

rated and permanently mounted to the power inlet panel.

Power Switch/Circuit Breaker

The power switch/circuit breaker (

B

in Figure 10-2) has

a rocker type actuator switch that will activate or deacti-

vate the AC power to the system. The power ON position

is marked with the internationally recognized I symbol,

the power OFF position is marked with the 0 symbol.

This power switch also integrates an appropriately sized

over-current protection circuit breaker function in the

generator.
If an over-current condition trips the circuit breaker, it

will automatically switch to the OFF position. If the over-

load current that caused the circuit breaker to trip is due

to a transient condition, the circuit breaker can be reset by

switching the actuator back to the ON position. If when

resetting the circuit breaker after it has tripped, it imme-

diately trips again, there is likely an internal system mal-

function, and the generator will require service.
Do not repeatedly try to reset the circuit breaker. If it

trips, this will only cause more damage to the generator.

Chassis Ground Stud

The chassis ground stud is used to attach a protective

earth ground to the generator. This will aid in the sup-

pression of electrical interference or radio frequency in-

terference (RFI) that is common in an industrial environ-

ment. The chassis ground stud is

C

in Figure 8-2. Proper

system grounding is discussed on Page 9.

Figure 8 - 2

120VAC Power Inlet Panel

LINE VOLTAGE:
100-120 Vac
50/60Hz, 10A

PE

120 Volt line cord

A

B

C

Page 100

iQ Series

Ultrasonic Generator/Power Supply ES User’s Manual

Dukane Manual Part No. 403-575-00