Lockout/Tagout

Procedure to use BEFORE making any internal
adjustments to the generator:

1. Push the generator's AC power switch/breaker

to the OFF position.

2. Unplug the generator's electrical cord from its

source.

3. Authorized personnel apply a lockout/

tagout (LOTO) device to the plug end of the

generator's electrical cord. Using a typical clam

shell type LOTO device:

1) Open the clam shell.

2) Place the electrical cord plug end inside the

shell.

3) Close the shell.

4) Secure the shell with its lock, and lock it.

4. Wait a minimum of five minutes for the

generator to discharge its electrical energy.

5. After taking these steps, make the necessary

adjustments to the generator.

Assuming the generator is being put back into

service. . .

Procedure to use AFTER making any internal
adjustments to the generator:

1. Authorized personnel remove the lockout/

tagout device from the plug end of the

generator's electrical cord. Using a typical clam

shell type LOTO device:

1) Unlock the protective shell.

2) Open the shell, exposing the electrical cord

end.

3) Remove the LOTO device, and set it aside.

2. Plug the generator's electrical cord into its AC

power source.

3. Push the generator's AC power switch/breaker

to the ON position.