Problem

Possible Solution

Troubleshooting

Unit power-up sequence stops, and front panel ON/OFF

button is flashing RED rapidly.

Operation of the front panel ON/OFF button at
power up

:

• Steady Green - Generator is ready to cycle.

• Red - Generator is in standby mode.

• Slow Flashing Red - Generator is charging the internal

power supplies.

• Fast Flashing Red - AC line over/under voltage de-

tected or internal power supply failure.

-

Continued

NOTE

If troubleshooting does not provide satisfactory re-

sults, please contact Dukane Corporation (see Sec-

tion 9 - Contacting Dukane

) for servicing. The iQ ES

generator and iQ Explorer are serviceable only by

Dukane personnel. Unauthorized attempts to service

either product will void any warranty.

See the error message Tables for

Servo and Pneumatic

presses following this page.

NOTE

Page 81

Dukane Manual Part No. 403-575-00