After pressing Teach, you will see a window similar to

the one shown in Figure 4-12.
Place an unwelded part into the fixture. Press both opti-

touch activation switches to jog the horn down to within

0.010 - 0.030 inches above the part. The stroke position

of the thruster will be shown in the Current Position

box. Once you are at the desired position, press Set to

program that distance. Select Exit, and follow instruc-

tions to Home the machine.

Figure 4-13

iQ Explorer, Select Trigger Method

Select

Trigger

Method,

Normal

Figure 4-12

iQ Explorer, Teach Start Sensing Distance

Servo Step 9 - Select Trigger Method

Still on the Process Settings tab, select Normal as the trigger

method.