Pneumatic Step 8 - Post Weld Settings

Figure 4-33

iQ Explorer, Process Settings > Post Weld > Hold Method > Hold Time

Select Time.

Program in a time of 0.500 seconds.

See Figure 4-33.

After the weld process (In this example setup, Collapse

Distance has a programmed value.), the welder will shut

off the ultrasound signal and continue to apply force for

the programmed time.

This phase is important to insure the molten plastic cre-

ated during the weld phase has a chance to solidify before

pressure is removed from the part.