Verifying Feature Operation

The iQ ES generator can be configured with several features that provide

interfaces from the control board to encoders and transducers outside the

system. These features include the following:

• Distance Encoder
• Power
• EPR (electronic pressure regulator) with Pressure Transducer
• Force Transducer (Load Cell)

Each of these features has a corresponding output on the iQ Explorer's

Cycle Data page. The Cycle Data page allows you to see the last cycle of

a control/monitor parameter. In order for values to appear in the computer

display, the system may have to be cycled or manipulated in some way.

Distance

To verify the distance feature, go to the Utilities page of iQ Explorer. Put

a check in the box (

p

) for Monitor Encoder Position

in order to view the

encoder position.

To check encoder function, either remove air pressure from the press or

depress the Emergency Stop switch that is grouped with the activation

switches.

As the thruster head moves up or down, the displayed value changes. The

value should increase as the head travels down and decrease as the head

travels up. On power-up, the reference mark (distance value) internal to the

iQ

generator is set between - 0.03 inches to - 0.10 inches.

This means that only after the head passes the reference mark, will the

distance data from the iQ generator be useful as it relates to the phases of

the weld cycle.

Page 85

Dukane Manual Part No. 403-575-00

Section 6 - Troubleshooting