Pneumatic Step 11 - Process Settings >Amplitude

Figure 4-36

iQ Explorer, Process Settings > Amplitude

Amplitude - This refers to the peak-to-peak displacement

of the horn at its workface. Amplitude settings are given

as a percent of the horn's nominal amplitude in the range

of 20% to 100%.

Select Local.

Then, at Weld, select 100%.

For a basic setup, leave Ramp Up Time and Ramp Down

Time at 0.150 and 0.000 respectively (the default settings).

See Figure 4-36 below

.

NOTE

Default settings for Ramp Up Time and

Ramp Down Time are dependent on the

frequency of the welding system.

Page 65

Dukane Manual Part No. 403-575-00

Section 4 - Operation

0.150

0.000

100

Local