Pneumatic Step 9 - Process Settings > Pressure

Figure 4-34

iQ Explorer > Process Settings > Post Weld > Pressure

For systems equipped with the Electronic Pressure

Regulator option, weld pressure parameters need to be

programmed in this section of the Process Settings

page. See Figure 4-34.
Downstroke

- This is the approach pressure before

Trigger. For a basic setup, program a value here equal to

Pressure 1.
Weld Pressure 1

- Program a pressure value based

on the force requirement suggested in the Initial Weld

Force chart. See Table 4-I and Figure 4-35

.

NOTE

Downstroke pressure must be pro-

grammed so that enough force will be

available to achieve the programmed

Trigger Force. If there is not enough

downstroke pressure, it may cause the

system to fault at Max Trigger Time.

Continued

Figure 4-35

Suggested Initial Weld Force

500
450
400
360
340
320
300
280
260
240
220
200
180
160
140
120
100

80
60
40
20

0

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

Fo

rce (pounds)

Linear Weld Joint (inches)

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36

500
150
400
360
340
320
300
280
260
240
220
200
180
160
140
120
100
80
60
40
20
0

Page 62

iQ Series

Ultrasonic Generator/Power Supply ES User’s Manual

Dukane Manual Part No. 403-575-00