Labconco Protector Controlled Atmosphere Glove Box User Manual

Page 57

Advertising
background image

Chapter 7: Accessorizing Your Glove Box

Product Service 1-800-522-7658

53

14. Moisture Monitors/Hygrometers

Moisture monitors or hygrometers allow the user to continuously monitor
moisture levels inside the glove box. Moisture monitors are normally
placed inside the main chamber to provide the best performance. Never
operate a transfer chamber vacuum evacuation on these sensitive
hygrometers as damage can occur.

Part #

Descriptions

5244900

1-1000 ppm Moisture Monitor/Hygrometer (Factory Set at 1-
1,000 ppm, with three settings of 1-10 ppm, 1-100 ppm, and 1-
1,000 ppm) 100V/115V – 50/60 Hz

5244901

1-1000 ppm Moisture Monitor/Hygrometer (Factory Set at 1-
1,000 ppm, with three settings of 1-10 ppm, 1-100 ppm, and 1-
1,000 ppm) 230V – 50/60 Hz – International

5244800

0-100% Hand Held Digital Hygrometer with Temperature
Display; measures relative humidity and temperature

5442200

Moisture Meter Probe and Calibration Stand -80 to 0°C dew
point range or 0 to 6000 ppm (Display is in dew point only),
100-115V, 50-60 Hz

5442201

Moisture Meter Probe and Calibration Stand -80 to 0°C dew
point range or 0 to 6000 ppm (Display is in dew point only),
230V, 50-60 Hz


15. Exterior Monitor Plumbing Kits (Part #’s below)

The exterior monitor plumbing kits provide attachment plumbing to
oxygen or moisture monitors outside the glove box. Note: The control
and accuracy of the oxygen and moisture monitors will be reduced due to
the surrounding ambient air rather than inert gas inside the glove box.

Part #

Descriptions

Used With

5442400 Plumbing Kit for Oxygen Monitor (0 to 10,000 ppm)

5244500, 01

5442500 Plumbing Kit for Monitor/Hygrometer with pump (0 to 10,000 ppm)

5244900, 01

16. Automatic Pressure Controller (for use with manual control

Protector Glove Boxes only)
The Pressure Controller provides the operator the convenience of
automatically regulating pressure and vacuum within the glove box
main chamber and transfer chamber. The end user can also automate
the evacuation/fill cycles up to 499 cycles for the main chamber and
up to 199 cycles on the transfer chamber. The vacuum and pressure
can be automatically regulated between -5 to +5 inches of water
gauge in the main chamber and between 0 to -29 inches of mercury
gauge in the transfer chamber. See illustration below and figures in
Chapter 3.

Part #

Electrical Configuration

5238600

100/115 Volts, 50/60 Hz operation

5238601

230 Volts, 50/60 Hz operation

5239100

Benchtop Bracket (required and ordered separate)