Replacing and filling io units with blood, Setup, Sternal io – Laerdal SimMan 3G Trauma User Manual
Page 29

29
SETUP
Replacing and Filling IO Units with Blood
The IO Pads supplied with SimMan 3G Trauma are disposable parts meant for single use.
Sternal IO
1 Attach the Sternal IO bag to the Sternal tube and close
off the pinch clamp.
2 Remove the Sternal IO pad from the manikin chest.
3 Remove the Sternal tube from the sternal pad.
4 Fill the sternal IO pad with 7ml of blood. Ensure the pad
is completely filled.
5 Reattach the Sternal tube to the Sternal IO pad.
6 Place the Sternal IO unit in the Sternal Chassis. Slide
the unit down and towards the neck, until it fits securely
under the top edge of the chassis.
7 Reattach the sternal IO pad
The sternal IO is now ready for simulation.
Note: If bits of plastic from the module get stuck in the needle, flush the needle with fluid to dislodge the obstruction.