August 30, 2002 Manual Version 1.0

2.2

It is also convenient to run the 115VAC power along with the high-speed serial bus cable to each
module(s) enclosure in the same flexible liquid tight conduit with ground, as indicated in Figure 2.2.



















Figure 2.2 Serial Bus Connections


3. Dual connector plugs are used for each optional module shown in Figure 2.2 for both the high-

speed serial bus and 115VAC power connection to the module. This allows both the serial bus and
power connections to be strung from module to module as shown in Figure 2.3.





















Figure 2.3 Dual Connector Plugs for Modules for Serial Bus and Power

USE THE SWITCH ON THE OPTION INSTALLED
AT THE FAR END OF THE CABLE FROM THE
OPERATOR TERMINAL TO TERMINATE THE
SERIAL BUS CABLE.

OPERATOR

TERMINAL

ENCLOSURE

O

P

T

I

O

N

1

O

P

T

I

O

N

5

O

P

T

I

O

N

3

O

P

T

I

O

N

2

O

P

T

I

O

N

4

SERIAL BUS CABLE AND POWER FOR
MODULES RUN IN SAME CONDUIT

GND

L1

L2

115VAC FROM
LAST MODULE

115VAC CONNECTOR PLUG
FOR THIS MODULE

115VAC TO NEXT
MODULE

16 GA RED, WHITE,
GREEN WIRES

16 GA RE D, WHITE,
GREEN WIRES

PLUGS INTO MODULE
CONNE CTOR HEADER
FOR THIS MODULE

SERIAL BUS CABLE
FROM LAST MODULE

SERIAL BUS CONNECTOR
PLUG FOR THIS MODULE

SERIAL BUS CABLE
TO NEXT MODULE

SHIELD MUST BE
CONNECTED TO PLUG

PLUGS INTO MODULE
CONNECTOR HEADER
FOR THIS MODULE

Cable Wire Color

Connector
Terminal

White

CANL

Orange

CANH

Blue

GND

Bare

Shield