The Programmable Limit Switch system should be configured before being put into operation. This
configuration allows the user to select the manner that the system can be reset and the use of speed
advanced outputs. The user is encouraged to look at all possible configuration options, and then choose
the options that best fit his applications.

To enter the Configuration screen, place the Run/Program key switch in the Program position, then
select the CONFIGURE softkey. A popup box which requests that the user enter the user configuration
code, highest order user password. After entry of the correct code, the Die Protection System
Configuration screen will appear. This screen is shown in Figure 7.5.

Stroke

Mode

Drive

Speed
Stroke
Speed

SPM

SPM

0
0

Order

Counter

SYSTEM STATUS

Counter OFF

Limit
Switch

CHANGE
CHANNEL
SETTING

EXIT

0

0

Program/Run Switch

TOP

Production

NEXT

PAGE

180

0

270

90

Ch Mode

Description

Status

State

CONFIGURE

RESET

FAULT

1

2

3

4

5

6

7

8

Normal

Timed Off

Toggle

Normal

Normal

Always Off

Always Off

Always Off

Feed Initiate

Air Blow Off

Parts Bin Select

Pilot Pin Release

Die Spray Lube

OK

OK

OK

OK

OK

OK

OK

OK

On

Off

Off

Off

Off

Off

Off

Off

Channel 1 Details

System Status: OK

Module Status: OK

Channel

Status

Ok

On Angle:

Off Angle:

270°

10°

Figure 7.4 Programmable Limit Screen

Stroke

Mode

Drive

Speed
Stroke
Speed

SPM

SPM

0
0

Order

Counter

SYSTEM STATUS

Counter OFF

PLS
Sys. Cfg.

CHANGE
SETTING

EXIT

0

0

Program/Run Switch

TOP

Production

RESTRICT

UNRESTRICT

Reset Resets All Channels:

Allow Speed Adjusted Outputs:

No
Yes

Figure 7.5 Programmable Limit Switch Configuration Screen


Advertising