LINK Systems OmniLink II Press Automation Control User Manual

Page 115

Advertising
background image

August 30, 2002 Manual Version 1.0

6.10

V+

SIGNAL

COM

V+

SIGNAL

COM

24 VDC

0 VDC

TO INPUT

NPN CONNECTIONS

V+

SIGNAL

COM

V+

SIGNAL

COM

24 VDC

0 VDC

TO INPUT

SERIES

PARALLEL

PNP CONNECTIONS

24 VDC

0 VDC

TO INPUT

SERIES

V+

SIGNAL

COM

V+

SIGNAL

COM

24 VDC

0 VDC

TO INPUT

PARALLEL

V+

SIGNAL

COM

V+

SIGNAL

COM

V+

SIGNAL

COM

24 VDC

0 VDC

TO INPUT

SINGLE

TO INPUT

24 VDC

0 VDC

SINGLE

V+

SIGNAL

COM

Figure 6.4 Solid State Sensors Single, Series, and Parallel Connections

Section 6.5 Die Protection Input Types and Their Uses

Each die protection channel can be programmed for any one of nine different die protection types:
Static, Cyclic, Transfer, In Position, 1 Part Detection Edge, 1 Part Pass, 2 Part Detection Edge, 2 Part
Detection Pass, and Custom. In addition, any input can be set to Not Used if desired.

Sensor logic is assigned descriptive names such as Static, Cyclic, and 1 Part Pass. Although these
names best describe the applications for which they are normally used, their use should not be limited by
their assigned name. For example, if a channel requires the logic of a 1 Part Pass and the sensor is not
actually detecting a part out, 1 Part Pass logic should still be used. Each channel can have its own
description. Although the 1 Part Pass logic is employed, the assigned description can indicate the
precise use of the channel.

Section 6.5.1 Static

Static inputs are used for sensors that monitor events that are independent of the production machine
cycle. Examples are sensors monitoring end of stock and stock buckling. If the input is programmed as