Tethered stylus, Installing a tethered stylus, A-10 – Datalogic Scanning 4420 User Manual

Page 98

Advertising
background image

Accessories

A-10

Falcon

®

4400 Series with Windows

®

CE

2. Insert the top tab of the handle into the slot at the top of the handle

recess (refer to

Figure A-11

).

3. Replace the screws located just above the battery cover’s latch dials.

4. The process is complete upon successful test of the trigger function.

Tethered Stylus

An optional Tethered Stylus is available
for use on any of the Falcon 4400
series models. The Tether attaches the
stylus to the Falcon unit, preventing
the stylus from accidentally becoming
lost or misplaced.

Installing a Tethered Stylus

If your Falcon did not come with a Tethered Stylus, it can be easily installed.

To install a Tethered Stylus on the Falcon 44xx complete the following steps:

1. Turn the Falcon face-down. Ensure that power is OFF.

2. Using a Phillips screwdriver, remove the 6 mm screw at the bottom of

the Stylus holder.

3. Use the longer 16 mm screw included with the Tethered Stylus kit to

attach the Tethered Stylus to the Falcon.

4. Slide the other end of the Tether through the Stylus.

Tether

CAUTION

Do not use the 16mm long screw that came with the Tethered Stylus without the
Tether. Damage to internal components could occur if the screw is used without
the Tether, since the screw is longer than the standard 6 mm screw used without
the Tether.