How to replace the stylus

Lock the tone arm.
Remove the protective cap from the stylus.
Pull the stylus in the direction of the arrow (A) and remove it.
Put in the new stylus following the reverse procedure.
Replace the protective cap on the stylus.

How to disassemble the cartridge

Lock the tone arm.
Remove the stylus (see section above).
Release the pick-up head by pushing the cartridge in the

direction of the arrow.

Disconnect the four wires at the level of the pick-up head.

How to install a new cartridge

Connect the link wires.
Push the cartridge into the head shell
Re-position the stylus
Place the protective cap on the stylus.