0

LIGHTING

INSTRUCTIONS

WARNING: You must operate

this fireplace with the fireplace

screen in place. Make sure fire-

place screen is installed before

running fireplace.

NOTICE: During initial operation

of new fireplace, burning logs

will give off a paper-burning

smell. Open damper or window

to vent smell. This will only last

a few hours.

1. STOP! Read the safety information, page

19, column 2.

2. Make sure equipment shutoff valve is fully

open.

3. Set selector switch in OFF position.

WARNING: Burner will come

on automatically within one

minute when the selector switch

is in the ON position after the

pilot is lit.

4. Press in and turn control knob clockwise

to the OFF position.

5. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the

safety information, page 19, column 2. If

you don’t smell gas, go to the next step.

6. Press in and turn control knob counter-

clockwise

to the PILOT position.

Press in control knob for five (5) seconds

(see Figure 38).

Note: You may be running this heater for

the first time after hooking up to gas sup-

ply. If so, the control knob may need to be

pressed in for 30 seconds or more. This will

allow air to bleed from the gas system.

7. With control knob pressed in, press and

release ignitor button. This will light pilot.

The pilot is attached to the front burner. If

needed, keep pressing ignitor button until

pilot lights.

O

F

F

PIL

OT

LO

IH

AUTO
OFF
ON

O

N

Figure 38 - Control Knob and Ignitor

Button Location (Shown as Supplied, No

Control Options)

Control Knob

Ignitor Button

Selector Switch

Flame Adjustment
Knob

Note: If pilot does not stay lit, contact a

qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure, page 21.

8. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

• If control knob does not pop out when

released, contact a qualified service

person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4

through 8.

9. Slightly push in and turn control knob coun-

terclockwise

to the ON position.

10. Wait one minute and switch selector switch

to the ON position to light burner.

11. Set flame adjustment knob to any level

between HI and LO.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Figure 39 - Pilot (Propane/LP)

Ignitor
Electrode

Pilot Burner

Figure 40 - Pilot (Natural)

Pilot Burner

Ignitor
Electrode

OPERATING FIREPLACE

Continued

Advertising