ASSEMBLING AND ATTACHING
OpTIONAL pERIMETER TRIM
(Included with Mantel Accessory)

IMPORTANT:

If you are recessing the firebox in a

wall, do not attach perimeter trim at this time. See

Built-In Fireplace Installation, page 11.
Note:

The instructions below show assembling

and attaching perimeter trim to fireplace.

1. Remove packaging from three pieces of pe-

rimeter trim.

2. Locate four perimeter screws, two adjusting

plates with set screws and two shims in the

hardware packet.

3. Align shim under adjusting plate as shown in

Figure 6.

4. Slide one end of adjusting plate/shim in slot

on mitered edge of top perimeter trim (see

Figure 6).

5. Slide other end of adjusting plate/shim in slot

on mitered edge of side perimeter trim (see

Figure 6).

6. While firmly holding edges of perimeter trim

together, tighten both set screws on the adjust-

ing plate with slotted screwdriver.

7. Repeat steps 1 through 6 for other side.

8. Tighten trim hanging screws (#10 x 6.25

shoulder) into holes in cabinets. Place the

assembled trim onto fireplace cabinet. Align

hanging notches on trim with hanging screws

on side of fireplace (see Figure 7). Push trim

firmly into place, sliding hanging notches over

hanging screws.

INSTALLATION

Continued

Figure 7 - Attaching Perimeter Trim to

Fireplace

Figure 6 - Assembling Perimeter Trim

Side Trim

Top
Trim

Slot

Mitered
Edge

Slot

Shim

Set Screws

Adjusting
Plate

Trim
Hanging
Screws

Assembled
Trim

Hanging
Notches
on Trim

INSTALLATION CLEARANCES

WARNING: Maintain the

minimum clearances. If you can,

provide greater clearances from

floor, ceiling and adjoining wall.

Carefully follow the instructions below. This will

ensure safe installation.
Minimum Clearances For Side Combustible
Material, Side Wall and Ceiling

A. Clearances from the side of the fireplace

cabinet to any combustible material and wall

should follow diagram in Figure 8.

Example: The face of a mantel, bookshelf,

etc. is made of combustible material and

protrudes 3

1

/

2

" from the wall. This combus-

tible material must be 4" from the side of the

fireplace opening (see Figure 8).

B. Clearances from the top of the fireplace opening

to the ceiling should not be less than 42".

Minimum Clearance to Combustible Materials

Top: 42", Left and Right Sides: 16"

Bottom and Rear: 0"

Figure 8 - Minimum Clearance for

Combustible to Wall

*Minimum 16" from Side Wall

Example

*