CLEANING AND

MAINTENANCE

WARNING: Turn off fireplace

and let cool before cleaning.

CAUTION: You must keep

control areas, burner and cir-

culating air passageways of

fireplace clean. Inspect these

areas of fireplace before each

use. Have fireplace inspected

yearly by a qualified service

person. Fireplace may need

more frequent cleaning due to

excessive lint from carpeting,

bedding material, pet hair, etc.

WARNING: Failure to keep

the primary air opening(s) of

the burner(s) clean may result in

sooting and property damage.

BURNER INjECTOR HOLDER AND
pILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount

of air to mix with the gas. This provides a clean

burning flame. Keep these holes clear of dust, dirt,

lint and pet hair. Clean these air inlet holes prior to

each heating season. Blocked air holes will create

soot. We recommend that you clean the unit every

three months during operation and have heater

inspected yearly by a qualified service person.

We also recommend that you keep the burner

tube and pilot assembly clean and free of dust and

dirt. To clean these parts we recommend using

compressed air no greater than 30 PSI. Your local

computer store, hardware store or home center

may carry compressed air in a can. You can use a

vacuum cleaner in the blow position. If using com-

pressed air in a can, please follow the directions on

the can. If you don’t follow directions on the can,

you could damage the pilot assembly.

1. Shut off the unit, including the pilot. Allow

the unit to cool for at least thirty minutes.

2. Inspect burner, pilot and primary air inlet holes

on injector holder for dust and dirt (see Figures

48 and 49).

3. Blow air through the ports/slots and holes in

the burner.

4. Check the injector holder located at the end

of the burner tube again. Remove any large

particles of dust, dirt, lint or pet hair with a

soft cloth or vacuum cleaner nozzle.

5. Blow air into the primary air holes on the

injector holder.

6. In case any large clumps of dust have now

been pushed into the burner repeat steps 3 and

4 above.

Clean the pilot assembly also. A yellow tip on the

pilot flame indicates dust and dirt in the pilot as-

sembly. There is a small pilot air inlet hole about

2" from where the pilot flame comes out of the

pilot assembly (see Figure 49). With the unit off,

lightly blow air through the air inlet hole. You may

blow through a drinking straw if compressed air

is not available.

Figure 48 - Injector Holder On Outlet

Burner Tube

Figure 49 - Pilot Inlet Air Hole

Burner
Tube

Pilot
Assembly

Pilot Air
Inlet Hole

Ports/Slots

Burner
Tube

Injector Holder (May
Be Brass or Aluminum
Depending on Model)

Primary Air Inlet Holes (Shape
of Holes May Vary by Model)

LOGS

• If you remove logs for cleaning, refer to Install-

ing Logs, page 17, to properly replace logs.

• Replace log(s) if broken or chipped (dime-sized

or larger).

Advertising