Wiring diagram, Specifications, Replacement parts – Desa FPVF33PRA User Manual

Page 29: Technical service, Service hints

Advertising
background image

www.desatech.com

113109-01C

9

WIRING DIAGRAM

Note:

For proper operation of optional accessories,

the wires from the switch to the control must be

connected exactly as shown.

SPECIFICATIONS

VYGF33NRC and FPVF33NRA

• Rating: 20,000/30,000

• Gas Type: Natural Gas

• Ignition: Piezo

• Pressure Manifold: 3.5" W.C.

• Inlet Gas Pressure (in. of water):

Maximum - 10.5", Minimum* - 5"

• Shipping Weight: 122 lbs.
VYGF33PRC and FPVF33PRA

• Rating: 20,000/33,000

• Gas Type: Propane/LP Gas

• Ignition: Piezo

• Pressure Manifold: 8.0" W.C.

• Inlet Gas Pressure (in. of water):

Maximum - 14", Minimum* - 11"

• Shipping Weight: 122 lbs.

* For input adjustment

AUTO

OFF

ON

Thermopile

REPLACEMENT PARTS

Note:

Use only original replacement parts. This

will protect your warranty coverage for parts

replaced under warranty.

pARTS UNDER WARRANTY

Contact authorized dealers of this product. If

they can’t supply original replacement part(s),

call DESA Heating Products’ Technical Service

Department at 1-866-672-6040. When calling

DESA Heating Products, have ready

• your name and address

• model and serial numbers of your fireplace

• how fireplace was malfunctioning

• type of gas used (propane/LP or natural gas)

• purchase date

Usually, we will ask you to return the part to the

factory.

pARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they

can’t supply original replacement part(s), call

DESA Heating Products at 1-866-672-6040 for

referral information. When calling DESA Heating

Products, have ready

• model number of your fireplace

• the replacement part number

TEChNICAL SERVICE

You may have further questions about installation,

operation or troubleshooting. If so, contact DESA

Heating Products’ Technical Service Department at

1-866-672-6040. When calling, please have your

model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ techni-

cal services web site at www.desatech.com.

SERVICE hINTS

When Gas pressure Is Too Low

• pilot will not stay lit

• burner will have delayed ignition

• fireplace will not produce specified heat

• for propane/LP unit, propane/LP gas supply

may be low

You may feel your gas pressure is too low. If so,

contact your local gas supplier.

Advertising