Product identification, Safety information – Desa FPVF33PRA User Manual

Page 4

Advertising
background image

www.desatech.com

113109-01C

4

O

F
F


P

ILO

T

O

N

H

I




L

O

SAFETY INFORMATION

Continued

1. This appliance is only for use with the type of

gas indicated on the rating plate. This appliance

is not convertible for use with other gases.

2. Do not place propane/LP supply tank(s) in-

side any structure. Locate propane/LP supply

tank(s) outdoors (propane/LP units only).

3. If you smell gas

• shut off gas supply

• do not try to light any appliance

• do not touch any electrical switch; do not

use any phone in your building

• immediately call your gas supplier from

a neighbor’s phone. Follow the gas

supplier’s instructions

• if you cannot reach your gas supplier, call

the fire department

4. This fireplace shall not be installed in a bed-

room or bathroom.

5. Do not use this fireplace as a wood-burning

fireplace. Use only the logs provided with the

fireplace.

6. Do not add extra logs or ornaments such as

pine cones, vermiculite or rock wool. Using

these added items can cause sooting. Do not

add lava rock around base. Rock and debris

could fall into the control area of fireplace.

7. To prevent the creation of soot, follow the

instructions in Cleaning and Maintenance,

page 24.

8. Before using furniture polish, wax, carpet

cleaner or similar products, turn heater off. If

heated, the vapors from these products may

create a white powder residue within burner

box or on adjacent walls or furniture.

9. This fireplace needs fresh air ventilation to run

properly. This fireplace has an Oxygen Depletion

Sensing (ODS) safety shutoff system. The ODS

shuts down the fireplace if enough fresh air is not

available. See Air for Combustion and Ventila-

tion, page 5. If fireplace keeps shutting off, see

Troubleshooting, page 25.

10. Do not run fireplace

• where flammable liquids or vapors are

used or stored

• under dusty conditions

11. Do not use this fireplace to cook food or burn

paper or other objects.

12. Do not use fireplace if any part has been

exposed to or under water. Immediately call

a qualified service technician to inspect the

fireplace and to replace any part of the control

system and any gas control which has been

under water.

13. Do not operate fireplace if any log is broken.

Do not operate fireplace if a log is chipped

(dime-sized or larger).

14. Turn fireplace off and let cool before servicing.

Only a qualified service person should service

and repair fireplace.

15. Operating fireplace above elevations of 4,500

feet could cause pilot outage.

16. To prevent performance problems in

propane/LP units, do not use propane/LP

fuel tanks of less than 100 lbs. capacity

(propane/LP units only).

17. Provide adequate clearances around air

openings.

PRODUCT

IDENTIFICATION

Figure 1 - Log Base Assembly

Piezo
Ignitor

Optional
Remote
Control

Control
Knobs

Firebox
Hood

Firebox
Support

Log Set (VYGF shown)

Remote Selector
Switch (Optional)

Top Outer
Casing

Blower Assembly
(Optional)

Screen
Assembly

Figure 2 - Fireplace

Louver