Connecting to Indexer with Differential Outputs

(Many High Speed Indexers have Differential Outputs)

Connecting to indexer with Sourcing Outputs

Connecting to Indexer with Sinking Outputs

High Speed Digital Inputs (STEP, DIR)

The -S drives include two high speed inputs labeled STEP and DIR. They accept 5 volt single-ended or differential

signals, up to 2 MHz.

STEP and DIR Inputs are configured using the ST Configurator software.

The inputs can connect to an indexer, a master encoder or CNC handwheel for following applications, or they can

be used for connecting sensors, switches and other electronic devices. They can be used as the run/stop and

direction inputs for velocity (oscillator) mode.

Connection diagrams follow.

ST5/10-S

COM

DIR-

DIR

DIR+

STEP-

STEP

STEP+

Indexer

with

Sourcing

Outputs

ST5/10-S

+5V OUT

DIR+

DIR

DIR-

STEP+

STEP

STEP-

Indexer

with

Sinking

Outputs

STM23

DIR+

DIR+

DIR-

DIR-

STEP+

STEP-

STEP+

STEP-

Indexer

with

Differential

Outputs