Captiview configuration – Doremi CaptiView User Manual

Page 12

Advertising
background image

D2K.DP.000469.DRM

Page 12 of 27

Version 2.1

Doremi Labs

Figure 7: List of Devices - Closed Caption Example

Click the Add button (Figure 7).

The user will now be back to the Device Manager GUI to finish configuring the device.

2.2.2 CaptiView Configuration

To finish configuring the device, complete the fields in the Closed Caption Configuration window
(Figure 8).

Check the Enabled box to enable this feature.

It is recommended to leave the default settings as they are, except for the Auditorium

field.

In the Auditorium field, choose any channel other than 0. For example, choose 1, 2, 3,

etc., but do not leave the channel set at 0. The number, once saved, will be saved to the
USB transmitter which then must be power-cycled by unplugging and then re-plugging
the transmitter. This applies to software versions 2.0.10 and higher.

Note: To change the current auditorium number while using software versions 2.07 or below,
contact Doremi Technical Support to receive a hot fix. In software version 2.0.10 and higher, the
user can change the auditorium setting from the Device Manager GUI.

Define the Play Offset, Idle Text, and Idle Time.

o Play Offset: This feature offsets the Closed Captioning data in the form of

milliseconds.

o Idle Text: The default text that is shown on the display.
o Idle Time: The time it takes for default Idle Text to appear after loss of input.

Click the Save button.

Add

Button

Closed

Caption

Advertising