Smpte 430-10 protocol set up via serial port – Doremi CaptiView User Manual

Page 22

Advertising
background image

D2K.DP.000469.DRM

Page 22 of 27

Version 2.1

Doremi Labs

4.2 SMPTE 430-10 Protocol Set Up Via Serial Port

Remove the AccessLink or CaptiLink from packing and begin to set up near a power

outlet and computer that has a serial port.

The serial cable required for a proper connection is a female to female pin to pin cable,

which should be provided in the package.

o Serial connection settings are: Speed 115200, Data bits: 8, Stop bits: 1, Parity:

None, Flow control: None

o Connect and switch the device on and wait for it to boot.

When the unit is done booting up, login as root.

o Password for root is: "veeone"
o It is recommended to change the root password by typing the following command

and following the on-screen instructions: "passwd"

4.2.1 Configuring the IP Address for AccessLink or CaptiLink

To configure the IP of the AccessLink or CaptiLink, type the following command:

o echo -n xxx.xxx.xxx.xxx > /doremi/etc/ip_addr (xxx.xxx.xxx.xxx = the desired

IP address) and then press the Enter key.

To configure the netmask, type the following command:

o echo -n xxx.xxx.xxx.xxx > /doremi/etc/netmask and then press the Enter key.

To configure the gateway, type the following command:

o echo -n xxx.xxx.xxx.xxx > /doremi/etc/gateway and then press the Enter key.

4.2.2 Adding the IP Address of a Digital Cinema Server to the AccessLink

or CaptiLink

To add the IP address, type the following command:

o echo -n xxx.xxx.xxx.xxx > /doremi/etc/s430-10/ip.conf

Power cycle the AccessLink or CaptiLink for the changes to take effect.

Connect the CaptiView Transmitter to the USB port on the AccessLink or CaptiLink and

go back to Section 2 of this manual to finish the setup.

Advertising