3. INSTALLATION
operation manual d06, chapter 3 - Installation - page 5 of 10
The digital audio level processor d06 can aknowledge specific device statuses
via parallel GPO (Tally) lines.
Use to :
monitor the d06 status
Connector :
D-SUB 25pin
female panel jack
Pin assignment of the connector :
Pin
Signal name
Functions
1
Tally 1 normally closed
2
Tally 1 normally opened
Defined by d06 config
3
TALLY 2 common
4
Tally 3 normally closed
5
Tally 3 normally opened
Defined by d06 config
6
TALLY 4 common
7
Tally 5 normally closed
8
Tally 5 normally opened
Defined by d06 config
9
Tally 6 common
10
Tally 7 normally closed
11
Tally 7 normally opened
Defined by d06 config
12
TALLY 8 common
13
+ 5V
110 Ohm
14
TALLY 1 common
15
Tally 2 normally closed
16
Tally 2 normally opened
Defined by d06 config
17
TALLY 3 common
18
Tally 4 normally closed
19
Tally 4 normally opened
Defined by d06 config
20
TALLY 5 common
21
Tally 6 normally closed
22
Tally 6 normally opened
Defined by d06 config
23
TALLY 7 common
24
Tally 8 normally closed
25
Tally 8 normally opened
Defined by d06 config
Screen
-5V
GND of do6 chassis
Electrical specifications :
Tally output relay :
common / normally closed / normally opened
24V - 1A
125V - 0,5A
P
max
= 62,5VA
3.7.3
GPO (TALLY)