5. OPERATION
operation manual d06, chapter 5 - Operation - page 7 of 8
Table of preset parameters and their values :
Preset name :
TV-U
R -U
R-SP
TV-L
Parameter name :
GAIN
0.0dB 0.0dB 0.0dB
OL
Operating Level
-18dBFS
-9dBFS -9dBFS -18dBFS
LEVELLER AGC
Range :
10dB 10dB 10dB 10dB
LEVELLER AGC
Time :
40sec. 40sec. 20sec. 20sec.
LEVELLER AGC
Silence Gate:
-50dBFS -50dBFS -40dBFS -50dBFS
LEVELLER AGC
ITU BS.1770:
ON ON ON ON
TRANSIENT PROC
Processing:
mid mid hard hard
TRANSIENT PROC
Range:
10dB 10dB 15dB 10dB
PEAK
Limiter Threshold
-9.0dBFS 0.0dBFS 0.0dBFS -9.0dBFS
PEAK LIMITER
Processing:
UNI UNI SPEECH
LIVE
MODE
stereo stereo stereo stereo