Signamax Model -065-7700 User Manual
Page 164

Hardened Managed PoE Ethernet Switch
User’s Manual 163
Location:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use snmp-server location command to specify and no snmp-server
location command to remove location for SNMP.
3.
Command Syntax:
snmp-server location LOCATION
no snmp-server location
LOCATION The location for SNMP.
4.
Example:
The following example specifies location (location) for SNMP:
switch_a(config)#snmp-server location location
switch_a(config)#
Contact:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use snmp-server contact command to specify and no snmp-server
contact command to remove contact for SNMP.
3.
Command Syntax:
snmp-server contact CONTACT
no snmp-server contact
CONTACT The contact for SNMP.
4.
Example:
The following example specifies contact (contact) for SNMP:
switch_a(config)#snmp-server contact contact
switch_a(config)#
Trap Community Name: