Signamax Model -065-7700 User Manual
Page 166

Hardened Managed PoE Ethernet Switch
User’s Manual 165
Cold Start Trap:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use snmp-server trap-type enable coldStart command to enable cold start
trap for SNMP.
Use the no snmp-server trap-type enable coldStart command to disable
cold start trap for SNMP.
3.
Command Syntax:
(no) snmp-server trap-type enable coldStart
4.
Example:
The following example enables cold start trap for SNMP:
switch_a(config)#snmp-server trap-type enable coldStart
switch_a(config)#
Warm Start Trap:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use snmp-server trap-type enable warmStart command to enable warm
start trap for SNMP.
Use the no snmp-server trap-type enable warmStart command to disable
warm start trap for SNMP.
3.
Command Syntax:
(no) snmp-server trap-type enable warmStart
4.
Example:
The following example enables warm start trap for SNMP:
switch_a(config)#snmp-server trap-type enable warmStart
switch_a(config)#
Link Down Trap:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).