2 customer specification (141 settings) – Digi Counting Version 4.0 DC-190 User Manual

Page 13

Advertising
background image

18

DC-190 Ultra Count Installation Manual

4.2

Customer Specification (141 Settings)

To configure customer specifications, press and hold the

REZERO

key and enter

141

using the numeric keypad.

SPC00

appears in the

WEIGHT

display and configuration of four bits (for SPEC 0) appears in

QUANTITY

display.

Follow the procedure described in Section 4.1 on page 17 to update the SPEC settings for the 141 access code.

SPEC

Default

Bit 3

Bit 2

Bit 1

Bit 0

0

0000

Transfer Tare Weight

0: No (hold tare)
1: Yes (transfer tare)

Tare Accumulation

0:

No (overwrite tare)

1:

Yes (add to existing
tare)

Terminator (RS-232 only)

0: Carriage return
1: Carriage return +

linefeed

Piece Weight Selection

0: Unit wt per 1000
1: Average piece wt

(APW)

1

0000

Power Auto Off Function: Function used to preserve and extend battery life. All four bits are used to
specify the number of minutes (binary) before the scale enters autopower off mode.Examples below show
the binary code, time delay, and description. Settings can range from 0–15 minutes in 1-minute
increments.

Binary Code
8421 Time (min) Description
0000

0

Autopower off is disabled.

0111

7

If net weight is zero and no motion for 7 minutes, scale goes into autopower off mode.

1111

15

If net weight is zero and no motion for 15 minutes, scale goes into autopower off mode.

NOTE: Powering down means that accumulated value is lost and not retained upon power up. However,
all total inventory values stored with item codes are retained.

2

1000

Scale Specification

00: Gram (no units switching)

01: Kg

10: Lb

11: Not used

NOTE: Values 01 and 10 allow Lb/Kg units

switching if SPEC 2, bit 1 is set 0.

Kg/Lb Lamp Enable

0: Yes
1: No

Inventory Display by Net/
Gross Key

0: No (Net/Gross toggle)
1: Yes (INVENT key
shows inventory quantity)

3

0000

RS-232 Port Commands (D-sub)

00:

Standard RS-232 (PC, force balance)

01:

TM-U295 ticket printer

10:

TM-U200 (with or without cutter)

11:

TM-U200 (with feed for tear-off)

Print Commands (8-pin DIN)

00:

BCP-30 (barcode printer, force balance)

01:

TM-U295 ticket printer

10:

TM-U200 (with or without cutter)

11:

TM-U200 (with feed for tear-off)

4

1001

Set New Item Code
During Normal Mode

0:

Yes

1:

No

Insufficient Sample Level

00:

0.1%

01:

0.2%

10:

0.0%

Negative Counting

0: No
1: Yes

5

1011

Sampling Time for Unit
Weight Calculations

0:

10 times

1:

5 times

Unit Weight
Auto-Recomputing

0:

Press PIECES key

after adding number of
pieces
1:

Scale automatically

recomputes after
adding number of
pieces without pressing
PIECES key

Date Order

00:

Year, Month, Day

01:

Day, Month, Year

11:

Month, Day, Year

6

1001

Display Accuracy of
Unit Weight

0:

No

1:

Yes

Clear Key Operation

0:

Clear all data

1:

Clear last character

RS-232 Continue
Sending Rate to PC

0: High
1: Low

Auto Shift to Next
Character After Two Digits
of Teraoka Code Entry

0: No (requires

+

key)

1: Yes

Table 4-1. DC-190 141 Settings

Advertising