Weight and Measurement Specifications (142 Settings)

To configure weight and measurement specifications, press and hold the

REZERO

key and enter

142

using the

numeric keypad.

SPC20

appears in

WEIGHT

display and configuration of four bits (for SPEC 20) appears in

QUANTITY

display. Follow the procedure described in Section 4.1 on page 17 to update the SPEC settings for the

142 access code.

SPEC

Default

Bit 3

Bit 2

Bit 1

Bit 0

20

none

Minimum Display (PORT 1, Scale 1)
MUST BE SET PRIOR TO CALIBRATION!

00: 2

01: 1

10: 5

11: 10

Minimum Display (PORT 1, Scale 2)
MUST BE SET PRIOR TO CALIBRATION!

00: 2

01: 1

10: 5

11: 10

21

none

Eltron Printer Selection

0:

Eltron Model 2722

1:

Eltron Model 2742
or 2642

NOTE: Must be set to
0 if an Eltron printer is
not being used.

Weight Decimal Point Position (PORT 1, Scale 1)
MUST BE SET PRIOR TO CALIBRATION!

000: 00000

011: 00.000

001: 0000.0

100: 0.0000

010: 000.00

101: .00000

22

none

Not used

Weight Decimal Point Position (PORT 1, Scale 2)
MUST BE SET PRIOR TO CALIBRATION!

000: 00000

011: 00.000

001: 0000.0

100: 0.0000

010: 000.00

101: .00000

23

0000

Display Resolution for Scales 1, 2, 3, and 4.
(Specify Not Used for force balance.)

00: 1/10000

01: 1/5000

10: 1/2500

11: Not used

Zero Setting Range

00: +Unlimited/–10% FS

01: ±2% FS

10: ±10% FS

11: Not used

24

0000

Masked Display at
Minus Weight

0:

Gross

1:

Net

Display at Minus Weight

0:

Minus display

1:

Masked

Zero Lamp Lighting
Method

0:

Gross

1:

Net

Low Battery (turn off
display when low battery)

0: No
1: Yes

25

00_0

Scale Starting Method

0:

Automatic

1:

Manual (must
press REZERO key
on startup)

Internal Resolution
Protected by Span
Switch

0:

No (internal
resolution can be
viewed by pressing
REZERO * * +)

1:

Yes (protected until
internal span
switch pressed)

Scale Type

0:

Single scale

1:

Dual scale

NOTE: If you are not
connected to a
dual-platform scale, or
do not have two scales
wired into Cable PORT
1, set this bit to 0 (single
scale). Selecting 1 (dual
scale) can damage the
console’s electronic
components.

Gross Mode Available

0: Yes (allows gross

mode selection from
keypad)

1: No (inhibits gross

mode; switching not
allowed)

26

0000

Zero Tracking When
Tare Is Present

0: Yes
1: No (zero tracking is
off with tare in system)

Rezero with a Tare
Weight

0: Yes
1: No

Initial Start Range

00: +Unlimited/–10% FS

01: ±2% FS

10: ±10% FS

11: Not used

Table 4-2. DC-190 142 Settings