3 clearing accumulated data, 6 other operations, 1 set new vendor name – Digi Counting Version 4.0 DC-190 User Manual

Page 23: 2 set new operator name, 3 set new batch print quantity, 4 set new sequence number

Advertising
background image

Scale Operations

29

illuminated and the display shows the quantity of parts remaining.

6. Remove a number of parts from the container and press the

key again. The

MEMORY

annunciator is

illuminated and the display shows the quantity of parts remaining.

NOTE:

If SPEC 32, bit 1 (Auto Exit from Part Accumulation and Reduction Mode) is set to 0, the scale will not auto

exit from displaying the total amount. To return to the weighing mode, press the

CLEAR

key.

6.5.3

Clearing Accumulated Data

To clear accumulated data, press the

*

key.

6.6

Other Operations

The following operations, added in software Version 4.02 and 4.04, can all be performed while the DC-190 Ultra
Count is in normal mode.

6.6.1

Set New Vendor Name

In software Version 4.02 or later, a new vendor (company) name can be scanned into the DC-190 Ultra Count by
doing the following:

1. Scan the

VENDOR NAME

barcode using the bar code board (see Section 10.9 on page 59).

2. Use the alphanumeric bar codes to scan up to 48 characters for the vendor name.

3. When complete, scan the

ENTER

bar code.

SPEC 44, bit 2, (input company name with bar board) must be set to 1 to use this function (see page 24).

6.6.2

Set New Operator Name

In software Version 4.02 or later, a new operator name can be scanned into the DC-190 Ultra Count by doing the
following:

1. Scan the

OPERATOR NAME

barcode using the bar code board (see Section 10.9 on page 59).

2. Use the alphanumeric bar codes to scan up to 32 characters for the operator name.

3. When complete, scan the

ENTER

bar code.

SPEC 44, bit 3, specifies whether the operator name is held in memory or is cleared after each use (see page 24).

6.6.3

Set New Batch Print Quantity

In software Version 4.04 or later, the number of labels printed for a batch can be changed by doing the following:

1. Press and hold the

REZERO

key and enter

111

using the numeric keypad.

2. The display shows the batch print quantity. Use the numeric keypad to enter the number of labels to

print.

3. Press the

*

key to store the batch print quantity, then press

MODE

to exit programming mode and return

to weighing mode.

Batch print quantity can also be set using a scanner and the

BATCH PRINT

barcode (see Section 10.9 on page 59).

6.6.4

Set New Sequence Number

In software Version 4.04 or later, the sequence number can be reset by doing the following:

1. Press and hold the

REZERO

key and enter

112

using the numeric keypad.

2. The display shows the sequence number. Use the numeric keypad to enter the new sequence number.

3. Press the

*

key to store the sequence number, then press

MODE

to exit programming mode and return to

weighing mode.