Characteristics

Case

Dimension = 350mm (W) x 250mm (H) x 130mm (D).

Weight = 4.7Kg.

Color = RAL7035.

Power

Item

Voltage

Current Consumption

Comment

DC Input

18V~26V, Typical 24V

150mA

Microphone Output

Maximum level = 6dBu.

Output Impedance = 100Ohm.

THD @ 1kHz < 0.1%.

Bandwidth @ -3dB = 200Hz ~ 20kHz.

Front Panel Speaker

Impedance = 8Ohm.

Maximum Power @ 1kHz = 1W.

THD @ 1kHz < 1%.

Bandwidth @ -3dB = 200Hz ~ 20kHz.

Cable length

100m(control and power on the same cable)

900m(when power line connects to junction box).

Comes standard with Junction box (JB) and CAT5 cable (1.5)

4.2.5.4

LED Indicators

The CD-16,CD-8 microphone console offers general VACIE (Voice alarm control and indicating
equipment) indicators LED as well as configurable button status LED.

General system indicators

The CD-16,CD-8 has three different main LED indicators to show different status of the CD-16,CD-8
and VACIE system: Power, Fault and Evac states.

In order to check for the LEDs condition, every 35 seconds both Fault and Evac blinked once.

Power LED: Indicates the presence of power on the CD-16,CD-8.

Fault LED: The fault LED is permanently lit if a fault state in the VACIE system has been
engaged.

Evac LED: The Evac LED is permanently lit if a evacuation state in the VACIE system has
been engaged.