Gain reduction (dB): Indicates the current amount of gain reduction.

o

Graphic: By clicking on the graphic button, this will open the Compressor-Limiter graphic
edition window, see below. You can adjust the limitation ratio by moving the red cursor, the
limiter threshold level and compression ratio by moving the upper blue cursor and the limiter
threshold range with the upper yellow cursor. You can adjust the compressor threshold level
by moving the lower blue cursor and the compressor threshold range with the lower yellow
cursor.

5.9

3rd Party Control

5.9.1

Communication Protocols

5.9.1.1

Notifier

The purpose of this document is to clarify the development tasks for communication between ATEIS
Voice Alarm System (VAS) and NOTIFIER Fire Panel (FP). This document is based on the NOTIFER
Functional Specification ID3000 Series of Intelligent Fire Alarm Control Panels Protocol for RS232
link to third-party equipment, and on the different e-mails we exchange during the last weeks.

Physical support

RS232 interface.

Full-duplex mode (Half-duplex mode will not be developed).

Baud rate configurable.

8 data bits.

1 stop bit.