Clearance to combustibles – Avalon Firestyles 796-1990 to 1993 User Manual

Page 15

Advertising
background image

Page 15

FREESTANDING INSTALLATION - SPECIFICATIONS

REQUIRED FLOOR PROTECTION:

Front = 16" NOTE: Front floor

protection is
measured from the
door opening.

Sides = 6"

Back =

6"

}

}

6 "

16" From Door Opening

6 "

CLEARANCE TO COMBUSTIBLES:

Backwall

Sidewall

A

B

E

D

Single Wall Connector

A. Sidewall to unit .........................

B. Backwall to unit.........................

C. Cornerwall to unit .....................

D. Connector to sidewall..............

E. Connector to backwall.............

F. Connector to cornerwall ..........

Reduced Clearance *

A. Sidewall to unit .........................

B. Backwall to unit.........................

C. Cornerwall to unit .....................

D. Connector to sidewall..............

E. Connector to backwall.............

F. Connector to cornerwall ..........

996

Flush

Top Flue

14"

14 1/2"

11"

23 1/2"
15 1/2"
19 1/2"

14"

9 1/2"
7 1/2"

23"
10"

15 1/2"

996

Extended

45

o

Flue

14"

17 1/2"

11"

23 1/2"
15 1/2"
16 1/2"

16"
14"

7 1/2"

25"
10"
12"

Cornerwall

C

F

Cornerwall

F

C

*

Components required for alcove, mobile home,
and reduced clearance installations are one of
the following listed double wall connectors and
chimney systems.

¥ DURAVENT model DVL with DURA-PLUS chimney
¥ AMERI-TEC model DCC with model HS chimney
¥ SECURITY model DP with SECURITY model ASHT or S2100

chimney

¥ METAL-FAB model DW with model TG chimney
¥ SELKIRK METALBESTOS model DS connector with model SSII

chimney

¥ OLIVER MACLEOD PROVENT model PV connector with model

3103 chimney

¥ GSW-JAKES EVENS SUPERPIPE 2100
¥ Standard Masonry Chimney with any one of the

above listed connectors