MASONRY FIREPLACE INSERT INSTALLATION (Cont.)

Installation Using a Direct Connection (Continued)

9.

To install the surround panels, follow the directions listed in the section "INSTALLING SURROUND
PANELS" . NOTE: Surround panels are not required for a direct connection if a block-off plate is
used.

Follow the installation instructions in reverse order for periodic inspection and cleaning.

SIDE VIEW OF FIREPLACE INSERT DIRECT CONNECTION

Non-Combustible
Material

Optional Surround
Panel

Block-off Plate

Remove Damper or
Wire it Open

Stainless Steel
Chimney Connector
Must Extend to Clay
Flue Liner or at least
one foot beyond
Block-off Plate

Insulation
(Optional)

Airtight Insulated
Clean-Out

Clay Flue Liner with
Required Air Space

Block-off Plate
Insulation

18" Min.

996 Extended 45 Flue Shown
Here Ð Follow the clearances
for the 996 Flush Top Flue
when that model is used.

Follow the directions on the previous page for installation.