Fireplace insert - specifications (continued) – Avalon Firestyles 796-1990 to 1993 User Manual

Page 34

Advertising
background image

Page 34

FIREPLACE INSERT - SPECIFICATIONS (Continued)

FLOOR PROTECTION:

Hearth of 38 5/8" width and 18" depth when the insert is in place (see "E" and "F" below).

CLEARANCE TO COMBUSTIBLES:

996

Flush

Top

Flue

996

Extended

45

o

Flue

A. Adjacent

Sidewall to Insert

B. Side Facing

C. Top Facing

(Facing with
Shield)

D. Mantle to Insert

(Mantle with
Shield)

E. Minimum Floor

Protection-Front

F. Minimum Floor

Protection-Side

14"

13"

29 1/2"
14 1/2"

31 1/2"
16 1/2"

18"

8"

14"

13"

29 1/2"
14 1/2"

31 1/2"
16 1/2"

18"

8"

COMBUSTIBLE SIDEWALL

COMBUSTIBLE MANTLE

A

B

C

D

E

F

Fireplace Facing

Surround Panel

Combustible Surface

Combustible Surface

NOTE: For clearances, use this clearance diagram or the clearance diagram on the safety label attached
to the back of the appliance.

LEVELING BOLTS

If your fireplace is stepped down from the hearth, you will be required to use the leveling bolts located
within the hardware package.

Prior to placing the insert
in the fireplace opening,
measure the step-down.
Screw the 1/2" bolts
provided into the threaded
holes in the back corners
of the insert body and
adjust them to match the
step-down measurement.
As you install the insert the
leveling bolts may need
further adjustment. This
may be done by tilting the
insert slightly and turning
the bolts.

BOTTOM VIEW

Leveling
B o l t s