EP1258 ­ Technical Data

Technical data

EP1258­0001

EP1258­0002

Fieldbus

EtherCAT

Fieldbus connection

2 x M8 socket (green)

Number of inputs

8

Input connections

M8

M12

Nominal input voltage

24 V

DC

 (­15%/+20%)

Input filter

10 µs

"0" signal voltage

­3...+5 V (similar to EN 61131­2, Type 3)

"1" signal voltage

+11...+30 V (similar to EN 61131­2, Type 3)

Input current

typically 3 mA (similar to EN 61131­2, Type 3)

Module electronic supply

derived from control voltage Us

Module electronic current
consumption

typically 120 mA

Sensor supply

derived from control voltage Us

Sensor current consumption

max. 0.5 A total, short­circuit proof

Power supply connection

Feed: 1 x M8 plug, 4­pin
Onward connection: 1 x M8 socket, 4­pin

Resolution time stamp

1 ns (Channel 0/1)

Precision of the time stamp

10 ns (+ input delay) (Channel 0/1)

Precision of the distributed clocks

< 100 ns (Channel 0/1)

Process image

8 input bits , 36 byte time stamp

Electrical isolation

Control voltage/fieldbus: yes

Permissible ambient temperature
during operation

­25°C ... +60°C
0°C ... +55°C (according to cULus, see UL Requirements)
0°C ... +55°C (according to ATEX, see special conditions)

Permissible ambient temperature
during storage

­40°C ... +85°C

Vibration / shock resistance

conforms to EN 60068­2­6 / EN 60068­2­27

EMC resistance/emission

conforms to EN 61000­6­2 / EN 61000­6­4

Protection class

IP65, IP66, IP67 (conforms to EN 60529)

Installation position

variable

Approvals

CE, cULus, ATEX