4 technical data, 1 permissible ambient and operating conditions, 1 single-phase connection – BECKHOFF AX5000 1,5 A - 40 A User Manual

Page 17

Advertising
background image

BECKHOFF

Drive Technology

4 Product description

AX5000

Version : 4.6

17

4.4

Technical data

UL-Listing!
It is essential to observe chapter 3.3 if you wish to operate an AX5000 in

USA or Canada.

4.4.1

Permissible ambient and operating conditions

Ambient / operating conditions

Permissible values

Ambient temperature during operation 0 °C to +50 °C

Ambient temperature during transport /

storage

-25 °C to +70 °C

Air humidity

5 % to 95 %, non-condensing

Pollution degree

2 according to EN 60204/EN 50178

Corrosion protection

Normally not required.

Under extreme operating conditions separate

measures must be agreed with the manufacturer.

Operating altitude

up to 1000 m above sea level

Installation position

vertical

Ventilation

Total device current ≤ 3 A: free convection

Total device current > 3 A: built-in temperature-

controlled fan

Protection class

IP 20

Vibration test (EN 60068-2-6)

Frequency range: 10-500 Hz

Amplitude: 10-58 Hz = 0,075 mm pk-pk

59-500 Hz = 1 g

Shock test (EN 60068-2-27)

Half sine wave amplitude: 5 g

Duration: 30 ms

Number of shocks: 3 per axis and direction

(total 18)

Repetitive shock test (EN 60068-2-27) Half sine wave amplitude: 5 g

Duration: 30 ms

Number of shocks: 1000 per axis and direction

(total 6000)

EMC

Category C3 - standard

Category C2, C1 - auxiliary filter required

4.4.2

Electrical data - single-channel servo drive (AX51xx)

4.4.2.1

Single-phase connection

Electrical data

AX5101

AX5103

AX5106

Rated output current

1.5 A

3 A

4.5 A

Minimum channel current at full current

resolution

0.35 A

1 A

1 A

Max. output current

(1)

4.5 A

7.5 A

13 A

Rated supply voltage

1x 100

-10%

– 240

+10%

V

AC

Max. DC link voltage

890 V

DC

Rated apparent power

Advertising