12 x07 – internal and external brake resistor – BECKHOFF AX5000 1,5 A - 40 A User Manual

Page 27

Advertising
background image

BECKHOFF

Drive Technology

4 Product description

AX5000

Version : 4.6

27

AX5000-xxxx-0200 (Hardware 2)

Terminal point

Connection

Output current

T-

OCT – and temperature

T+

OCT + and temperature

PE

Signal pair screen

B-

Brake GND

B+

Brake (U

p

) +

2.2 A max.

Note

Output current
The specified output current is the maximum value. The actual value

depends on your current configuration.

4.7.12 X07 – internal and external brake resistor

(Only AX5140)

Terminal point

Connection

PE

Protective conductor

+ R

B

External brake resistor +

+ R

Bint

Internal brake resistor +

– R

B

Brake resistor GND

Note

Operation of AX5140
Commissioning the AX5140 can only be carried out when the terminal

points "+R

Bint

" and "+R

B

" are bypassed (delivery state) or an external brake

resistor is connected (terminal points "+R

B

" and "-R

B

"). If these measures

are not taken then the AX5140 will be stopped with the error message

"FD4B – undervoltage"

Advertising