2 electrical installation – BECKHOFF AX5000 1,5 A - 40 A User Manual

Page 32

Advertising
background image

5 Installation

BECKHOFF

Drive Technology

32

Version : 4.6

AX5000

5.2

Electrical installation

UL-Listing!
It is essential to observe chapter 3.3 if you wish to operate an AX5000 in

USA or Canada.

DANGER

Serious risk of injury through electric shock!
Due to the DC link capacitors dangerous voltage may persist at the DC link

contacts "X02" after the servo drive has been disconnected from the mains

supply. After disconnecting the servo drive wait 5 minutes and measure the

voltage at the DC link contacts DC+ and DC-. The device is safe once the

voltage has fallen below 50 V.

WARNING

Caution – Risk of injury through electric shock!

Before installation, wiring and commissioning it is essential to read the

section on "Safety".

Before installing, uninstalling or connecting the servo drive and the

motors please note the following:

- Remove all relevant mains fuses.

- Switch off the main system switch and secure it with a lock.

- Put up a warning sign.

The control and power connections for the motors may be live, even if

the motor is prevented from rotating by the internal brake.

Attention

Destruction of the equipment!

Check the rated voltage and current of the servo drive and the connected

motors.

When the AX5000 is disconnected from the mains supply (emergency

stop, mains contactor etc.), wait at least 3 minutes before starting again

or query the status of the IDN "P-0-0205" (see documentation of the

“IDN-Description”).

Advertising